Gas Side Cleaner RXSOL
GAS SIDE CLEANER is sprayed undiluted on a completely dry area on to the upper most point of the system.
GAS SIDE CLEANER Rx is sprayed undiluted on a completely dry area on to the upper most point of the system. It contains a “clinging agent” and will run around tubes/fins and drain onto the next bank. A steady spray on the top area should be maintained until the complete unit is soaked. Very large systems may require spraying at different sections.
GAS SIDE CLEANER RX is primarily intended for use in motor vessel exhaust gas heat recovery units of all designs. It can be used to clean fouled exhaust trunks. It is fully effective when used to wash down auxiliary and main boilers from the uptakes, through economizers, generating tube banks, superheaters, membrane walls, water walls and furnaces. It contains an additive to assist in the removal of vanadium.
Form | Liquid |
Colour | Yellow |
Odour | Charastics . |
Odor Threshold | No Information Available |
pH | 11 - 12 |
Relative density |
1.14 to 1.16 |
Boiling Point | 100 °C |
#GAScleaner_ManufacturerSupplier
#Gas_Cleaner
#GasCleaner_MuscatDubai
Gas Side Cleaner Rx manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai, Sharjah, UAE, Gulf, Middle East, Muscat Ruwi Barka Oman, Kenya Africa. Get the best quality of Gas Side Cleaner Rx at a competitive price from us. We have ready stock of Gas Side Cleaner Rx in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.
CLEANING PROCEDURE
- Check if the casing drains to the bilge are open and clear (as applicable)
- Open the turbocharger casing drain to the bilge (as applicable)
- Prepare spray equipment and connect gas side cleaner drum
- Spray gas side cleaner starting from the highest points, ensuring that enough product is applied to allow thorough wetting of tubes/fins below and especially out of sight
- Allow soaking for 30 - 60 minutes
- Wash off deposits, starting from the highest point, using a fresh water jet
- Keep checking the drains of the casings during wash down
- Inspect system thoroughly, repeat if necessary