FREE SHIPPINGFree shipping on all orders over 100000 INR.

Alkalinity Control

0
No votes yet

Product Qty Per Unit: 
20.00
Product usage unit: 
Ltr.

Negotiate Price

Product Delivery Locations: 
Mumbai, JNPT, Nhava Seva, Pirpav Jetty, Ballard Pier, Mumbai Port Trust, Butcher Island, ONGC EMR Shed, MIdc, Pune, Maharastra
Generic Name: 
Boiler Chemical to treat Water Alkalinity
Concentrated liquid alkaline product for corrosion and Calcium scale control in boilers.
Product Description: 

RXSOL-50-5002-020 is a concentrated liquid alkaline product for corrosion and Calcium scale control in boilers.  
Suitable for low-pressure boiler systems (0-32 bar), medium-pressure steam propulsion vessels (32-60 bar). And also suitable to used for high-pressure steam generating systems (60-84 bar).

Product Application: 

RXSOL-50-5002-020 provides the alkaline condition for hardness control to function correctly. Without the correct precipitation and subsequent blow down of hardness salt, scale would form. This would result in restriction in water flow, ineffective heat transfer and local corrosion. The end effect would be an inefficient boiler and ultimately component failure. RXSOL-50-5002-020 also provides the alkaline condition required for corrosion control, by neutralization of acidic gases

Product Procedure: 
Product Note: 
Product Technical Specification: 

Testing control procedure

  1. Test water sample from the water boiler as described in the direction of the  Alkalinity Test Kit ( p & m Total ) http://www.rxmarine.com/Alkalinity-test-kit
  2. Determine the present alkalinity value expressed as ppm CaCO3 .
  3. Desired level of 100-150 ppm as CaCO3.
  4. A control test for the alkalinity  of the water should be conducted after 3- 6 hours from the application.
  5.  
Product pack size: 
25 ltr, 50, 210 ltr. This chemical is used to treat Boiler Water Alkalinity.
Product alias: 
<p> GREEN AC, Alka active liquid, GC Concentrated Alkaline Liq , GC, Alka Treat, ACT 100 NORCHEM, Alkaline Treatment Liquid 9-512, Eazy Neutralise, ALKATREAT, Sodium Hydroxide Alkali control, PH Neutraliser, Maxtreat-3004, 551442, Alkanity Control 20 Ltr</p>

Testing control procedure

  1. Test water sample from the water boiler as described in the direction of the  Alkalinity Test Kit ( p & m Total ) http://www.rxmarine.com/Alkalinity-test-kit
  2. Determine the present alkalinity value expressed as ppm CaCO3 .
  3. Desired level of 100-150 ppm as CaCO3.
  4. A control test for the alkalinity  of the water should be conducted after 3- 6 hours from the application.

CHARACTERISTICS

  • Alkalinity balace mechnism to control corrosion.
  • It converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown. Treated as good salt-scale controler product.
  • Compatible with other BOILER chemicals
  • Tested with long and continious running plant for more then 20 Years and easy to apply and use.
  • Avoid contact with any acidic / oily - FAT materials.

Alkalinity Control works as PH Neutrilizer in Boiler system. Alkalinity control one of important boilere water treatment chemicals which plays very important role by controlling corrosion and solid deposits in boiler system.

Alkalinity control makes sludge in soft form, which can be easily blown down from bottom side of BOILER.

Other valuable Boiler Water Treatment Chemical product :

RXSOL-50-5020-025 Boiler Water Treatment Auto
RXSOL-40-4091-025  Scale and Corrosion Inhibitor for Cooling Water
RXSOL-40-4009-025 MICRO BIOCIDE Cooling Water 
RXSOL-50-5002-025 Alkalinity Control 
RXSOL-40-2000-025 RXSOL 2000 corrosion inhibitor 
RXSOL-40-4009-025 MICRO BIOCIDE Cooling Water
RXSOL-50-5021-025  Hardness Control Liquid

Boiler Water Treatment Chemicals Alkalinity Control manufacturer and supplier in India UAE Oman, Alkalinity Control is most valuable Boiler water Treatment chemicals to converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown. Alkalinity controller boiler chemical manufacturer and supplier in Mumbai, Chennai, Kolkata, Visakhapatnam, Surat, Gandhidham, Chennai Ennore, Paradip, Nashisk, Pune, Varanashi, Patna, Tata, Ranchi, Fujairah, Sharjah, Ajman, Abudhabi, Dubai, UAE Gulf, Barka, Ruwi Ghala, Muscat Oman, Nairobi, Kenya, Canada

Articles: 
Remarks: 


Mechanism: It converts calcium hardness into soft, non-adherent sludge that is easily removed by blowdown.

The presence of alkalinity in a water sample may be due to many different substances.  However, for the sake of simplicity, the presence of bicarbonate, carbonate, and hydroxide ions is commonly considered as alkalinity.  The points of change in colour of phenolphthalein and methyl orange indicators, which occur at pH 8.3 and pH 4.3 provide standard reference points which are almost universally used to express alkalinity.

Very high alkalinity values can be undesirable in an industrial water supply.  For example, the presence of a high methyl orange alkalinity should be avoided in boiler feed water because of the resultant carbon dioxide content of the steam.  Carbon dioxide usually is responsible for the corrosion of steam and return lines.  High boiler water alkalinities are also undesirable because the presence of high hydroxide ion concentration is the primary cause of caustic metal embrittlement. A very high boiler alkalinity can also lead to an undesirable carryover condition.  On the other hand, the alkalinity of boiler water must be sufficiently high to protect the boiler metal against acidic corrosion and to ensure precipitation of scale-forming salts.  Usual treatment approaches include setting both a minimum alkalinity level and an operating range.
 

Hydroxide alkalinity may be determined by adding barium chloride prior to titration to precipitate the carbonate ion from solution, allowing direct titration of the hydroxide alkalinity.  Measurement of hydroxide alkalinity is also used to control lime soda softeners.
 

In cooling water systems, alkalinity is of major importance since the total alkalinity of a water is one factor that must be considered when predicting the tendency for the water to precipitate calcium carbonate scale.  Depending on the choice of chemical treatments to protect against corrosion and scale formation, the operating alkalinity and pH ranges are chosen to balance these two features.

Alkalinity Titrimetric Method (0-200 ppm) 

Principle Theory

This test is based on the determination of alkalinity by titration with standard acid to the phenolphthalein colour change (or to a pH of 8.3) and to the methyl orange colour change (or a pH of 4.3).  For determination of hydroxide alkalinity only, barium chloride is added prior to titration to precipitate the carbonate ions.  Titration is then taken only to the phenolphthalein endpoint.  A pH meter may be used instead of the indicators to determine the endpoints of the titration.

  • MUMBAI PORT NHAVA SEVASupply can be done within 1 Hour for BPT-Nhava.
  • Mumbai JNPT Ship Chandler50% Discount on every Marine chemical purchase.
  • Largest Marine CHEM SupplierStock Turbha, KANDLA, Vizag, Kolkata, Chennai.
  • Email Price, MSDS, Tech supportmarinechemical @ gmail.com

Top Rated Products