Coil Brite RXSOL Air Conditioning System
This is specially formulated for use as a coil cleaner and filter adhesive for cooling coils of the air- conditioning systems.
RXSOL-16-1697-005 is a concentrated, high-foaming outdoor condenser coil cleaner and brightener. It effectively foams away stubborn,"baked on" lint, smoke film, insects, feathers, grass, leaves and other deposits from air cooledcondenser coils. The expanding foam pushes contamination out of the coil and is easily rinsed away with water. In addition to removing contaminants, the RXSOL COIL CLEANER formula effectively restores efficiency and reduces operating cost by removing hidden oxidation from the coil surfaces.
RXSOL-16-1697-005 is a special formulation of solvents and acids specifically blended for use in cleaning and brightening outdoor aluminum finned air cooled condenser coils.
Produced and packaged in our ISO 9001 registered facility.
CHARACTERISTICS:
Heavy foaming action.
Solvent-Acid blend (pH: <2.0).
Removes oxidation - Brightens aluminum.
Bright pink liquid.
#CoilBriteinUAE
#CoilBriteinOMAN
#CoilBriteAirCoolerCoilCleanersupplierInUAE
Coil Cleaner Air Conditioning System manufacturer and supplier in India - Middle East UAE GULF - Oman, Kenya Nairobi, Canada. RXSOL Coil Cleaner Air Conditioning System popular supplier in Mumbai, Kandla, Surat, Kolkata, CHennai, Vizag Visakhapatnam, Haldia, Fujairah Muscat, Abudhabi, Ajman, Dubai, Sharjah, Ghala, Barka Sohar Oman, Jinja Kampala, Uganada, CANADA
APPLICATION METHODS:
Low pressure, acid resistant tank sprayers are recommended.
Regardless of application method, avoid inhalation of mist or contact of liquid or mist with skin.
SUGGESTED INSTRUCTIONS FOR USE:
-
When handling RXSOL-16-1697-005 or any other strong chemical, be sure to wear chemical imperviousgloves,apron and splash goggles.
-
Determine required dilution ratio for the specific application. It is recommended to start with a dilution ratio of 10:1 and increase concentration until the desired results are achieved.
-
As with mixing all acids, place the desired amount of water into the tank and then add RXSOL-16-1697-005.
-
Turn off fans and allow hot coils to cool before applying.
-
Using plain water, wet both the condenser coil as well as the area surrounding the equipment. Wetting the coil with water aids in product penetration and performance.
- Apply the properly diluted product to the coil surface. Whenever possible, apply solution from the outlet side of the coil. Allow product to remain on surface, normally 5-10 minutes. Do not allow product to dry on the coil. Note: In extreme cases, application may have to be repeated to achieve desired results.
-
If foaming does not occur, check for extreme grease buildup which will slow cleaning process. Foaming may not occur if coil is coated or painted.
- Rinse coils, tools and surrounding area thoroughly after completing the coil cleaning process