Product code RXSOL-50-5020-020
- Generic name
- AUTO Treat One Shot Treatment Chemicals
- Pack size
- Boiler water Treatment One Shot Auto treatment chemicals available in 20 Kg and 30 Kg Liquid Pack
- Unit
- Ltr.
- Quantity per unit
- 20.00
RXSOL Boiler Water Treatment – AUTOTREAT
Product Name: Boiler Water Treatment AUTOTREAT
Brand: RXSOL
Product Category: Marine & Industrial Boiler Water Treatment Chemicals
Product Description
RXSOL AUTOTREAT is a multipurpose boiler water treatment chemical designed for the treatment and conditioning of boiler water in marine and industrial steam-generating systems.
It is intended to provide combined protection against scale formation, corrosion and sludge accumulation, helping maintain boiler efficiency, improve heat transfer and reduce maintenance requirements.
A properly formulated AUTOTREAT product can combine alkalinity control, hardness conditioning and sludge dispersion in a single liquid treatment.
Autotreat is a boiler water conditioner designed for optimum protection of ships boiler systems when used in conjunction with Oxygen Scavenger Plus. The product combines well known phosphate treatment with new polymer technology. This ensures that precipitates are kept soft and no adherent for easy removal by blow down. The product should always be used in conjunction with an oxygen scavenger, preferably Rxsol Oxygen Scavenger Plus. Note that this product is formulated for use in conjunction with good quality feed water.
Application
Key Features and Benefits
-
Scale Prevention: Helps prevent calcium and magnesium hardness deposits on boiler heating surfaces.
-
Corrosion Control: Maintains suitable alkaline conditions to minimize corrosion of boiler internal surfaces.
-
Sludge Conditioning: Converts residual hardness into manageable sludge that can be removed through blowdown.
-
Heat Transfer Efficiency: Reduces insulating deposits and associated energy losses.
-
Multipurpose Treatment: Combines several boiler water conditioning functions in one product.
-
Easy Dosing: Suitable for controlled dosing through a chemical dosing pump.
Autotreat is a boiler water conditioner designed for optimum protection of ships boiler systems when used in conjunction with Oxygen Scavenger Plus. The product combines well known phosphate treatment with new polymer technology. This ensures that precipitates are kept soft and no adherent for easy removal by blow down.
The product should always be used in conjunction with an oxygen scavenger, preferably Rxsol Oxygen Scavenger Plus. Note that this product is formulated for use in conjunction with good quality feed water.
Technical Specifications
Applications
RXSOL AUTOTREAT is suitable for consideration in:
-
Marine auxiliary boilers
-
Industrial steam boilers
-
Package boilers
-
Low- and medium-pressure boiler systems, subject to formulation and operating conditions
-
Boiler feedwater and internal water treatment programs
RXSOL Product Identification
|
Parameter |
Details |
|---|---|
|
Product name |
Boiler Water Treatment AUTOTREAT |
|
RXSOL product code |
RXSOL-50-5020-025 |
|
Chemical technology |
Phosphate–polymer treatment |
|
Physical form |
Liquid |
|
Primary function |
Scale, corrosion and sludge control |
|
Supplementary treatment |
RXSOL Oxygen Scavenger Plus |
|
Standard packing |
25 L |
Product information confirms the phosphate–polymer technology and recommends using AUTOTREAT with a separate oxygen scavenger.
Marine Chemicals
Other Names
Autotreat, BOILER WATER INHIBITOR ,GREEN BWT, DM-532, Auto Treat 20 Kg Liquid
Supply Locations
Boiler Water Treatment Marine Boiler Auto Treat Chemicals manufacturer and supplier in India, UAE Oman Nairobi. RXSOL AUTO Treat Boiler Water Treatment Chemicals supplier in Gahala Ruwi Barka Muscat Oman, Fujairah Sharjah Ajman, Abudhabi, Dubai, Mumbai, Surat Hazira, Gandhidham, Kandla, Mundra, Visakhapatnam, Gangavaram, Chennai Ennore, Haldia Kolkata, Paradip, Nairobi Kenya
Dosage
Recommended Dosage and Control
|
Boiler water P-alkalinity |
Indicative addition |
|---|---|
|
0 ppm |
2.4 L/ton |
|
50 ppm |
1.8 L/ton |
|
100 ppm |
1.2 L/ton |
|
150 ppm |
0.6 L/ton |
|
200 ppm |
No additional initial dose |
These figures are indicative, not a verified dose-response curve for every RXSOL production batch. Final dosing must follow the actual product strength, boiler operating pressure, feedwater analysis and boiler manufacturer's requirements.
RXSOL
Typical Reference Specifications
The following are published specifications for Wilhelmsen AUTOTREAT, provided as a reference benchmark rather than certified RXSOL batch specifications.
|
Property |
Reference value |
|---|---|
|
Appearance |
Light yellow liquid |
|
Specific gravity |
Approximately 1.10 |
|
pH |
13–14 |
|
P-alkalinity control |
150–300 ppm as CaCO₃ |
|
Condensate pH |
8.5–9.2 |
RXSOL-50-5020-025 does not replace dissolved oxygen control. Use an appropriate oxygen scavenger RXSOL-44-6119-025 and monitor boiler water alkalinity, phosphate, conductivity, chlorides and condensate quality.
Boiler Water Treatment Chemicals Full range ::: https://rxchemicals.com/Boiler-treatment-chemicals-INDIA-One-Stop-Boiler-Maintenance-Solutions
Marine Chemicals Full Range ::: https://marinechemical.in/marine-chemicals-full-range
The product should preferably be dosed continuously with a Rxsol Boiler Water Treatment Dosing Unit. Alternatively the product can be fed into the feed line by means of a by-pass pot feeder.
Dosage and control
Minimum dosage is 1.2 liters of Autotreat/ton of boiler capacity to reach a P-Alkalinity level of 100 ppm. For an untreated system it is recommended to initially bring the treatment up to a suitable level of 200 ppm p-Alkalinity. The dosage chart given below is for convenience to determine the amount of product required to elevate P-Alkalinity. Note that the table is based on reaching 200 ppm. P-Alkalinity.
Sampling and testing
A representative sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Spectrapak Test Kit instructions and log the results. It is important that regular testing is carried out to ensure that treatment levels are correct.