Cool Water Treat Corrosion Inhibitor
Cooling water Treatmanet Corrosion Inhibitor NCLT is specialized Cooling Water treatment chemicals for a closed re-circulating water system. Suitable for all types of engines where water circulation permitted. Major engine manufacturers such as MAN Diesel and Wartsila have a suggestion to use proper balance dose of Nitrite, Borate and organics based corrosion inhibitor in water circular line.
Liquid product, easy to use. Environmentally friendly, fully organic product, low toxicity. Effective against cavitation and erosion. Superior heat transfer properties. Compatible with hoses, gaskets and seals. Compatible with glycols for frost protection. Stable product - non-depleting. The product used for corrosion inhibition in many types of closed re-circulation system such as: - Diesel engine cooling water systems - Compressor cooling water systems - Centralised cooling systems - Hot water heating systems - Auxiliary machinery cooling systems.
Physical Properties
Density 1.06
Packing, Type 25 Ltrs
Colour Colourless
Appearance Liquid
Features of Cool Water Treat Corrosion Inhibitor
-
Contains Corrosion inhibitors for C.S, S.S, & Cu, which helps to extend equipment life & reduce maintenance costs.
-
Contains no heavy metals compatible with antifreeze, no environmental restrictions.
-
Completely water soluble, which enhances complete system protection.
-
Contains high concentrations of active inhibitors, thus dosage rates become more cost effective.
-
Cool Water Treat Corrosion Inhibitor is most effective at pH> 8.0.
-
Cool Water Treat Corrosion Inhibitor is formulated with a synergistic blend of nitrite and other Inhibitors.
-
Contains a blend of alkalis to offer metal passivation.
-
Contains a special dye to trace system leaks & observe Inhibitor Concentration.
-
Cool Water Treat Corrosion Inhibitor contain special Corrosion Inhibitors that can tolerate moderate heat fluxes.
-
Contains Corrosion Inhibitors for soft metals (weld joints).
RXSOL Cooling water Treatmanet Corrosion Inhibitor is an organic liquid corrosion inhibitor with low-toxic property provides long-life corrosion protection for closed cooling water systems RXSOL Cooling water Treatmanet Corrosion Inhibitor will protect all commonly used materials in engine cooling water systems, including aluminium. Cooling water Treatmanet Corrosion Inhibitor does not contain components subject to rapid depletion. Cool WATER treat is stable and biodegradable
Cool water Treat Corrosion Inhibitor manufacturer and supplier in Mumbai, Gandhidham, Chennai Ennore, Visakhapatnam, Kolkata, Haldia, Hazira, Surat, Vizag, Fujairah, Sharjah, Ajman, Dubai, Muscat Canada, SUDAN, Yemen, Nairobi Kenya
"Product Code" - Chemical Description SPECIFICATION .
| Sl. No. | Product Code | Chemical Description | Specification / Performance Requirement |
|---|---|---|---|
| 1 | RXSOL-44-6119-025 | Oxygen Scavenger – Sodium Bisulphite (For Water Injection) | To maintain DO below 20 ppb. Minimum strength 40%. Compatibility report with the membrane to be provided. |
| 2 | RXSOL-81-8171-025 | Injection Water Corrosion Inhibitor | Residual CI > 20% of dosing ppm. Fe in Injection Water < 0.05 ppm. |
| 3 | RXSOL-43-4098-025 | Biocide Disperser | SRB population < 100 cfu/mL. Minimum active ingredient concentration 50%. |
| 4 | RXSOL-42-1308-030 | Sodium Hydroxide (NaOH), 48 wt% Concentration | To maintain pH 10–11 during CEB and CIP and remove membrane fouling. Minimum concentration 48%. |
| 5 | RXSOL-43-8936-025 | Membrane Biocide for SRU & Wash Water Membranes | Polyglycol and DBNPA based. Must have compatibility certificate for DOW SRU membranes. Minimum active compound 20%. |
| 6 | RXSOL-25-3025-026 | Sodium Hypochlorite (NaOCl), 12.5 wt% Concentration | Maintain SRB population < 100 cfu/mL. Minimum concentration 12.5%. |
| 7 | RXSOL-19-1101-025 | Hydrochloric Acid (HCl), 25 wt% Concentration | To maintain pH 2–3 during CEB and CIP and remove membrane fouling. Minimum concentration 25%. |
| 8 | RXSOL-33-3302-025 | Scale Inhibitor / Antiscalant for SRU & Wash Water | Prevent scale formation in membranes. Maximum dosage rate 4 ppm. Must have compatibility certificate for DOW SRU membranes. |
| 9 | RXSOL-40-5024-025 | pH Controller | To maintain TEG pH > 7. Estimated quantity as per operational requirements. |
| 10 | RXSOL-33-3302-250 | Topside Scale Inhibitor | Residual SI > 20% of dosing ppm. Scaling Tendency Efficiency by Titration > 80%. |
| 11 | RXSOL-40-4029-030 | Topside Corrosion Inhibitor (Liquid) | Residual CI > 20%. ΔFe < 2 ppm. Corrosion Rate < 4 MPY. |
| 12 | RXSOL-40-4012-025 | Corrosion Inhibitor for Cooling Water | Residual CI > 20% of dosing ppm. Additional Monitoring Parameter: Corrosion Rate < 3 MPY. |
WHERE USED:
- RR WEST UNITS
- CBDC UNIT U-2026: USED IN FRESH COOLING WATER SYSTEM (U-2026) OF CBDC TO PROTECT CARBON STEEL AS WELL AS YELLOW METALLURGY OF FCW COOLERS. FROM CORROSION AND CONTAINS PH BUFFERS TO DEFEND THE SYSTEM AGAINST PH CHANGES.
NOTE :
- SHELF LIFE REQUIRED IS 2 YEARS (MINIMUM) FROM DATE OF PRODUCTION
Item Specs:
GENERIC TYPE: CORROSION INHIBITOR
FORM: LIQUID
SERVICE: WATER TREATMENT